A Continuous Emission Monitoring System (CEMS) measures air pollutants from industrial stacks around the clock. As a result, plants can track their emissions at all times. This article first explains how CEMS works. It then presents a CEMS installation project delivered by WCE’s RAT business unit.
CEMS continuously measures gases and particulates leaving a stack. Commonly monitored parameters include NOx, SO₂, CO, CO₂, O₂, opacity, particulate matter, and flow rate [1]. Under US Performance Specification 2, a CEMS has four major subsystems: the sample interface, the pollutant analyzer, the diluent analyzer (e.g., O₂), and the data recorder [2].
In Thailand, a Ministry of Industry notification issued in 2022 requires certain listed factory types to install stack emission monitoring instruments. These factories must also report data to the Department of Industrial Works [4][5]. For this reason, CEMS has become an essential system for large industrial plants.
First, an extractive system draws a sample from the stack through a probe and a heated sample line. The heated line prevents condensation. Next, a conditioning unit filters and dries the gas. Finally, the gas reaches analyzers inside a cabinet or shelter. Because the analyzers sit away from the hot, corrosive stack, technicians can maintain and calibrate them more easily [1]. In addition, ISO 10396 provides guidance on sampling for permanently installed automated gas monitoring systems [3].
In contrast, in-situ systems mount sensors directly on the stack. They measure either at a single point or across the stack (path). These systems need no sample transport. However, maintenance is harder because the equipment sits on the stack [1].
CEMS data must pass relative accuracy testing against reference methods during normal operation. In addition, operators run routine zero and span checks [2]. Meanwhile, a data acquisition system (DAS) records, calculates, and reports the results continuously.
The cover image shows three views from left to right. First, you can see equipment mounted on the stack wall. Next comes an equipment enclosure on the stack platform. Finally, the image shows the gas analyzer cabinet with its display. We used AI to edit all images so that no individual or client can be identified.
WCE’s RAT business unit provides automation, instrumentation, and control system services for industrial plants.
Contact: +66 65-937-6283 | international@wce.co.th | www.wce.co.th
We engineer your success.
[1] Mussatti, D.C., et al. (2002). EPA Air Pollution Control Cost Manual, Section 2, Chapter 4: Monitors (EPA/452/B-02-001). U.S. Environmental Protection Agency. https://19january2021snapshot.epa.gov/sites/static/files/2020-11/documents/cs2ch4.pdf
[2] U.S. EPA. 40 CFR Part 60, Appendix B – Performance Specifications (PS-2: SO₂ and NOx CEMS). https://www.law.cornell.edu/cfr/text/40/appendix-B_to_part_60
[3] ISO 10396:2007 Stationary source emissions—Sampling for the automated determination of gas emission concentrations for permanently installed monitoring systems. https://scc-ccn.ca/standardsdb/standards/8119700
[4] Department of Industrial Works. (2024). Public hearing summary: Draft Ministry of Industry Notification on special instruments for reporting air pollution from factory stacks (No. …). (In Thai) https://www.diw.go.th/webdiw/wp-content/uploads/2024/02/r29022567-01.pdf
[5] Office of Natural Resources and Environmental Policy and Planning. (2022). Over 600 factories are required to install CEMS. (In Thai) https://www.onep.go.th/?p=66679