• Project Name: Saving Energy in Hydraulic Systems with Variable-Speed Motor Control: Principles and a WCE RAT Case Study
  • Client: Cold-rolled steel sheet manufacturer in Thailand
  • Description: Hydraulic system energy-saving upgrade with an inverter control panel, 100% completed

Summary

Many hydraulic systems in industrial plants run their pumps at constant speed. This happens even when the machine needs little pressure or flow. As a result, excess energy is lost as heat. Matching motor speed to the actual load with a variable frequency drive (VFD) is a widely studied approach to hydraulic system energy saving. This article first explains the principles using technical sources. It then presents a job by RAT (Robotics and Automation Technology and Engineering) as a WCE case study.

1. Why Adjusting Motor Speed Saves Energy

The U.S. Department of Energy (DOE) explains the affinity laws for variable-torque loads, such as centrifugal pumps and fans. Under these laws, input power varies with the cube of speed. Therefore, a 20% speed reduction can cut power by about half. In addition, DOE advises obtaining part-load drive efficiency data from suppliers when calculating actual savings [1].

2. Key Principles in Hydraulic Systems

2.1 Hydraulic Pumps Rarely Run at Full Load

In many operating periods, a hydraulic system only needs to hold pressure with little or no flow. However, if the motor keeps running at full speed, much of the energy goes to waste.

2.2 Hydraulic Power Units Driven by Variable-Speed Motors

A study in the journal Energies examined a hydraulic power source driven by a variable-speed motor. During pressure holding without flow, it found about 30% lower energy use than a conventional variable-displacement power source [2]. Still, this result comes from a specific research system. Actual savings in each plant depend on the load profile and system design.

2.3 Measurement Is Part of the System

Power meters on the control panel show actual electricity use before and after the upgrade. In addition, they support long-term tracking of results.

3. Case Study: Hydraulic System Energy Saving by RAT

  • Scope: Energy-saving upgrade of a hydraulic system with a new control panel housing three inverters
  • Panel front: Three power meters and a touch-screen HMI
  • Client: Cold-rolled steel sheet manufacturer in Thailand
  • Duration: 17 March – 18 September 2026 (about 6 months)
  • Progress: Plan 100% / Actual 100%

The cover image shows three views from left to right. First, you can see the inside of the control panel with three inverters and wiring. Next comes the new panel, installed next to the existing switchgear in the electrical room. Finally, the image shows the panel front with power meters and an HMI. We edited all images with AI so that no individuals or clients can be identified.

4. Observations

  • Upgrading an operating plant means fitting a new panel into the existing electrical system. For this reason, the team must schedule tie-ins to minimize production impact.
  • In addition, installing power meters from the start lets the client verify savings independently.

5. WCE Services

RAT (Robotics and Automation Technology and Engineering) provides automation, control, and energy-efficiency upgrades for industrial plants.

To discuss your project: +66 65-937-6283 | international@wce.co.th | www.wce.co.th
We engineer your success.

References

(Accessed 6 Oct 2026)
[1] U.S. Department of Energy, Advanced Manufacturing Office (November 2012). Adjustable Speed Drive Part-Load Efficiency. Motor Systems Tip Sheet #11, DOE/GO-102012-3730. https://www.energy.gov/sites/prod/files/2014/04/f15/motor_tip_sheet11.pdf
[2] Yan, Z., Ge, L. & Quan, L. (2022). Energy-Efficient Electro-Hydraulic Power Source Driven by Variable-Speed Motor. Energies, 15(13), 4804. https://doi.org/10.3390/en15134804

✉️

Purchasing Department : phaiboono@wce.co.th   |   Human Resources and Administration Department : hrmwce@wce.co.th   |   Sales Department : international@wce.co.th

Headquarters Bangkok

16 K&Y Building 5 Fl., Surasak Road, Silom Sub-District, Bangrak District, Bangkok, 10500

Sales Department: +66 (0) 6 5937 6283
Accounting (Bangkok): +66 (0) 81 986 7190
Procurement Department: +66 (0) 81 941 0128
Careers & Internships: +66 (0) 64 934 2684
Fax: +66 (0) 2233 6669

Factory Bang Saphan

9/1 Moo 4, BanKlangNa–YaiPloy Road, Maerumphueng, BangSaphan, PrachuapKhiriKhan 77140

Telephone +66 (0) 3290 6112 – 119
Sales Department: +66 (0) 6 5937 6283
Accounting (Factory): +66 (0) 81 149 0614
Procurement Department: +66 (0) 81 941 0128
Careers & Internships: +66 (0) 64 934 2684
Fax +66 (0) 3290 6120